Embedded Capacity Register
Dataset schema
Click to expand Click to collapse
JSON Schema
The following JSON object is a standardized description of your dataset's schema. More about JSON schema.
{
- "title":"embedded-capacity-register",
- "type":"object",
- "oneOf":,[
- {
- "$ref":"#/definitions/embedded-capacity-register"
}
] - "definitions":{
- "embedded-capacity-register":,{
- "properties":{
- "records":{
- "type":"array",
- "items":{
- "$ref":"#/definitions/embedded-capacity-register_records"
}
}
} - "records":
} - "properties":
- "embedded-capacity-register_records":{
- "properties":{
- "fields":{
- "type":"object",
- "properties":{
- "export_mpan_msid":,{
- "type":"string",
- "title":"Export MPAN / MSID",
- "description":"The core meter point administration number, a 13-digit reference used in MPAS to identify the relevant Metering Point. For generation and storage sites, the "Export" MPAN (or MSID for CVA registered sites) should be included. For "Accepted to Connect" generation or storage entries, please indicate "data not available". "
} - "import_mpan_msid":,{
- "type":"string",
- "title":"Import MPAN / MSID",
- "description":"The core meter point administration number, a 13-digit reference used in MPAS to identify the relevant Metering Point. For sites subject to a DSR contract and for storage sites, the "Import" MPAN (or MSID for CVA registered sites) should be included. For generation sites, including generators taking on-site supplies, please indicate "not applicable". For "Accepted to Connect" storage sites, please indicate "data not available"."
} - "customer_name":,{
- "type":"string",
- "title":"Customer Name ",
- "description":"Name of party that is connected or contracted to connect."
} - "customer_site":,{
- "type":"string",
- "title":"Customer Site ",
- "description":"Name of customer site/project name."
} - "address_line_1":,{
- "type":"string",
- "title":"Address Line 1",
- "description":"Address line 1 of the Customer Site."
} - "address_line_2":,{
- "type":"string",
- "title":"Address Line 2",
- "description":"Address line 2 of the Customer Site."
} - "town_city":,{
- "type":"string",
- "title":"Town/ City ",
- "description":"Town / City of the Customer Site. Missing data will show "data not available"."
} - "county":,{
- "type":"string",
- "title":"County ",
- "description":"County of the Customer Site."
} - "postcode":,{
- "type":"string",
- "title":"Postcode ",
- "description":"Postcode of the Customer Site. Missing data will show "data not available"."
} - "country":,{
- "type":"string",
- "title":"Country",
- "description":"GB country of the Customer Site."
} - "location_xcoordinate_eastings_where_data_is_held":,{
- "type":"string",
- "title":"Location (Xcoordinate): Eastings (where data is held)",
- "description":"Six digit British National Grid X coordinate of the Customer Site. Generally this is the same as the Point of Connection / Metering Point. In exceptional cases where the Point of Connection or Metering Point is not located at the Customer Site, the coordinates of the Customer Site is included. Missing data will show "data not available"."
} - "location_ycoordinate_northings_where_data_is_held":,{
- "type":"string",
- "title":"Location (ycoordinate): Northings (where data is held)",
- "description":"Six or seven digit British National Grid Y coordinate of the Customer Site. (In Northern Scotland, these will be seven digit coordinates.) Generally this is the same as the Point of Connection / Metering Point. In exceptional cases where the Point of Connection or Metering Point is not located at the Customer Site, the coordinates of the Customer Site is included. Missing data will show "data not available"."
} - "grid_supply_point":,{
- "type":"string",
- "title":"Grid Supply Point",
- "description":"The point of connection between the transmission system and the distribution system that is linked with the Customer Site. Missing data will show "data not available"."
} - "bulk_supply_point":,{
- "type":"string",
- "title":"Bulk Supply Point",
- "description":"The supply point on the distribution system (representing an EHV/EHV transformation level) that is linked with the Customer Site. If the site is connected in Scotland/ SP Distribution, then the Bulk Supply Point will show "data not applicable". Missing data from England/ Wales/ SP Manweb will show "data not available"."
} - "primary":,{
- "type":"string",
- "title":"Primary",
- "description":"The primary substation on the distribution system that is linked with the Customer Site. Missing data will show "data not available"."
} - "point_of_connection_poc_voltage_kv":,{
- "type":"string",
- "title":"Point of Connection (POC) Voltage (kV)",
- "description":"The voltage at the Point of Connection to the distribution system. Missing data will show "data not available"."
} - "licence_area":,{
- "type":"string",
- "title":"Licence Area ",
- "description":"Licence area Customer Site is connected within"
} - "energy_source_1":,{
- "type":"string",
- "title":"Energy Source 1",
- "description":"Meaning any of the below energy source types used in the production of electricity: Advanced Fuel (produced via gasification or pyrolysis of biofuel or waste) Biofuel - Biogas from anaerobic digestion (excluding landfill & sewage) Biofuel - Landfill gas Biofuel - Sewage gas Biofuel - Other Biomass Fossil - Brown coal/lignite Fossil - Coal gas Fossil - Gas Fossil - Hard coal Fossil - Oil Fossil - Oil shale Fossil - Peat Fossil - Other Geothermal Hydrogen Nuclear Solar Stored Energy (all stored energy irrespectve of the original energy source) Waste Water (flowing water or head of water) Wind Other Data not available "
} - "energy_conversion_technology_1":,{
- "type":"string",
- "title":"Energy Conversion Technology 1",
- "description":"Meaning any of the below technology types that export electricity onto a distribution system: Engine (combustion / reciprocating) Steam turbine (thermal power plant) Gas turbine (OCGT) Steam-gas turbine (CCGT) Fuel Cell Hydro - Run of river Hydro - Reservoir (not pumped) Hydro - Other Tidal lagoons Tidal stream devices Wave devices Photovoltaic Offshore wind turbines Onshore wind turbines Geothermal power plant Storage - Chemical Storage - Electrical Storage - Mechanical - Compressed Air (Adiabatic & Diabatic) Storage - Mechanical - Liquid Air Storage - Mechanical - Pumped Hydro Storage - Mechanical - Flywheel Storage - Thermal Storage - Electrochemical (Batteries) Storage - Other Interconnector Other Data not available "
} - "chp_cogeneration_yes_no":,{
- "type":"string",
- "title":"CHP Cogeneration (Yes/No)",
- "description":"Indicates whether the generation in the Customer Site forms part of a CHP scheme."
} - "storage_capacity_1_mwh":,{
- "type":"string",
- "title":"Storage Capacity 1 (MWh)",
- "description":"This is the energy capacity of the storage facility (MWh). Where energy source 1 is not an energy storage site, cell will show "data not applicable". Missing data will show "data not available"."
} - "storage_duration_1_hours":,{
- "type":"string",
- "title":"Storage Duration 1 (Hours)",
- "description":"Divide the storage capacity (MWh) by the Registered Capacity (MW) and round it down to the nearest 0.5 (half-hour). If the value is less than 0.5 before rounding, it could be rounded to 0.5 hours so that it is not zero. Where energy source 1 is not an energy storage site, cell will show "data not applicable". Missing data will show "data not available"."
} - "energy_source_energy_conversion_technology_1_registered_capacity_mw":,{
- "type":"string",
- "title":"Energy Source & Energy Conversion Technology 1 Registered Capacity (MW)",
- "description":"This is the Registered Capacity of the "Energy Source 1" expressed in MW."
} - "energy_source_2":,{
- "type":"string",
- "title":"Energy Source 2",
- "description":"Where there is more than one plant type at a site, the "Energy Source 2" and "Energy Source 3" fields would be used to show the energy source types additional to the "Energy Source 1". Meaning any of the energy source types stated above for the "Energy Source 1"."
} - "energy_conversion_technology_2":,{
- "type":"string",
- "title":"Energy Conversion Technology 2",
- "description":"Defined as above for “Energy Conversion Technology 1”."
} - "chp_cogeneration_2_yes_no":,{
- "type":"string",
- "title":"CHP Cogeneration 2 (Yes/No)",
- "description":"Indicates whether the generation in the Customer Site forms part of a CHP scheme."
} - "storage_capacity_2_mwh":,{
- "type":"string",
- "title":"Storage Capacity 2 (MWh)",
- "description":"This is the energy capacity of the storage facility (MWh). Where energy source 2 is not an energy storage site, cell will show "data not applicable". Missing data will show "data not available"."
} - "storage_duration_2_hours":,{
- "type":"string",
- "title":"Storage Duration 2 (Hours)",
- "description":"Divide the storage capacity (MWh) by the Registered Capacity (MW) and round it down to the nearest 0.5 (half-hour). If the value is less than 0.5 before rounding, it could be rounded to 0.5 hours so that it is not zero. Where energy source 2 is not an energy storage site, cell will show "data not applicable". Missing data will show "data not available"."
} - "energy_source_energy_conversion_technology_2_registered_capacity_mw":,{
- "type":"string",
- "title":"Energy Source & Energy Conversion Technology 2 Registered Capacity (MW)",
- "description":"This is the Registered Capacity of the "Energy Source 2" expressed in MW. Where Energy Source 2 is "data not available", the registered capacity will show "data not applicable"."
} - "energy_source_3":,{
- "type":"string",
- "title":"Energy Source 3",
- "description":"Defined as above for “Energy Source 2”"
} - "energy_conversion_technology_3":,{
- "type":"string",
- "title":"Energy Conversion Technology 3",
- "description":"Defined as above for “Energy Conversion Technology 2”"
} - "chp_cogeneration_3_yes_no":,{
- "type":"string",
- "title":"CHP Cogeneration 3 (Yes/No)",
- "description":"Indicates whether the generation in the Customer Site forms part of a CHP scheme."
} - "storage_capacity_3_mwh":,{
- "type":"string",
- "title":"Storage Capacity 3 (MWh)",
- "description":"This is the energy capacity of the storage facility (MWh). Where energy source 3 is not an energy storage site, cell will show "data not applicable". Missing data will show "data not available"."
} - "storage_duration_3_hours":,{
- "type":"string",
- "title":"Storage Duration 3 (Hours)",
- "description":"This is the Registered Capacity of the "Energy Source 3" expressed in MW. Where Energy Source 3 is "data not available", the registered capacity will show "data not applicable"."
} - "energy_source_energy_conversion_technology_3_registered_capacity_mw":,{
- "type":"string",
- "title":"Energy Source & Energy Conversion Technology 3 Registered Capacity (MW)",
- "description":"This is the Registered Capacity of the "Energy Source 3" expressed in MW."
} - "flexible_connection_yes_no":,{
- "type":"string",
- "title":"Flexible Connection (Yes/No)",
- "description":"Indicates whether the connection is subject to a flexible connection arrangement e.g. Active Network Management (ANM) during system normal conditions."
} - "connection_status":,{
- "type":"string",
- "title":"Connection Status ",
- "description":"“Connected" or "Accepted to Connect"?"
} - "already_connected_registered_capacity_mw":,{
- "type":"string",
- "title":"Already connected Registered Capacity (MW) ",
- "description":"This is the total Registered Capacity of generation already connected at the site expressed in MW."
} - "maximum_export_capacity_mw":,{
- "type":"string",
- "title":"Maximum Export Capacity (MW)",
- "description":"This is the total MW export capacity permitted as per the connection agreement."
} - "maximum_export_capacity_mva":,{
- "type":"string",
- "title":"Maximum Export Capacity (MVA)",
- "description":"This is the total MVA export capacity permitted as per the connection agreement. Where there is no storage or demand included in energy sources, then cell will show "data not applicable"."
} - "maximum_import_capacity_mw":,{
- "type":"string",
- "title":"Maximum Import Capacity (MW)",
- "description":"This is the total MW import capacity permitted as per the connection agreement. Where there is no storage or demand included in energy sources, then cell will show "data not applicable"."
} - "maximum_import_capacity_mva":,{
- "type":"string",
- "title":"Maximum Import Capacity (MVA)",
- "description":"This is the total MVA export capacity permitted as per the connection agreement."
} - "date_connected":,{
- "type":"string",
- "title":"Date Connected",
- "description":"Date the connection was provided in the case of a new connection. In cases where there was an existing connection, this is date the new equipment was connected."
} - "accepted_to_connect_registered_capacity_mw":,{
- "type":"string",
- "title":"Accepted to Connect Registered Capacity (MW)",
- "description":"This is the Registered Capacity of generation that is not already connected, but has been Accepted to Connect, expressed in MW."
} - "change_to_maximum_export_capacity_mw":,{
- "type":"string",
- "title":"Change to Maximum Export Capacity (MW) ",
- "description":"This is the new/additional MW export capacity (i.e. not yet connected) that has been accepted to connect as per the connection agreement."
} - "change_to_maximum_export_capacity_mva":,{
- "type":"string",
- "title":"Change to Maximum Export Capacity (MVA) ",
- "description":"This is the new/additional MVA export capacity (i.e. not yet connected) that has been accepted to connect as per the connection agreement."
} - "change_to_maximum_import_capacity_mw":,{
- "type":"string",
- "title":"Change to Maximum Import Capacity (MW) ",
- "description":"This is the new/additional MW import capacity (i.e. not yet connected) that has been accepted to connect as per the connection agreement."
} - "change_to_maximum_import_capacity_mva":,{
- "type":"string",
- "title":"Change to Maximum Import Capacity (MVA) ",
- "description":"This is the new/additional MVA import capacity (i.e. not yet connected) that has been accepted to connect as per the connection agreement."
} - "date_accepted":,{
- "type":"string",
- "title":"Date Accepted",
- "description":"Date the Customer accepted the connection offer from the DNO or IDNO."
} - "target_energisation_date":,{
- "type":"string",
- "title":"Target Energisation Date",
- "description":"Estimated date of energisation. This date is likely to change to reflect the latest date notified by customers."
} - "distribution_service_provider_y_n":,{
- "type":"string",
- "title":"Distribution Service Provider (Y/N)",
- "description":"Indicates whether a service is provided to the DNO."
} - "transmission_service_provider_y_n":,{
- "type":"string",
- "title":"Transmission Service Provider (Y/N)",
- "description":"Indicates whether a service is provided to the ESO or a TO."
} - "reference":,{
- "type":"string",
- "title":"Reference",
- "description":"Unique reference to the service(s) being provided."
} - "in_a_connection_queue_y_n":,{
- "type":"string",
- "title":"In a Connection Queue (Y/N)",
- "description":"Indicates whether the connection to the Customer Site is in a connection queue."
} - "distribution_reinforcement_reference":,{
- "type":"string",
- "title":"Distribution Reinforcement Reference",
- "description":"Unique reference to relevant distribution reinforcement required for connection."
} - "transmission_reinforcement_reference":,{
- "type":"string",
- "title":"Transmission Reinforcement Reference",
- "description":"Unique reference to relevant transmission reinforcement required for connection."
} - "last_updated":,{
- "type":"string",
- "title":"Last Updated",
- "description":"Date on which entry was last updated."
} - "query_disconnection":{
- "type":"string",
- "title":"Query Disconnection ",
- "description":""
}
} - "export_mpan_msid":
}
} - "fields":
} - "properties":
} - "embedded-capacity-register":
}