SPD LTDS Appendix 1 Circuit Data (Table 1)

Attachments

Click to expand Click to collapse

Dataset schema

Click to expand Click to collapse
Grid Supply Point
The unique name of the Grid Supply Point (GSP) a  substation is within.

No description available for this field.

Name (identifier)
grid_supply_point
Type
text
Sample
                       
Circuit From
Powerfactory code for starting node of circuit.

No description available for this field.

Name (identifier)
circuit_from
Type
text
Sample
                       
Circuit To
Powerfactory code for ending node of circuit.

No description available for this field.

Name (identifier)
circuit_to
Type
text
Sample
                       
No of ccts
Number of circuits.

No description available for this field.

Name (identifier)
no_of_ccts
Type
integer
Sample
                       
Voltage (kV)
The operating voltage of the asset.

HV >= 6.6kV and < 33kV

EHV = 33kV

Transmission: Generally 132kV and above, but includes some lower voltages managed by our SPT licence area.

No description available for this field.

Name (identifier)
voltage_kv
Type
integer
Sample
                       
Resistance [R] (pu on 100MVA)
Resistance per unit on 100MVA.

No description available for this field.

Name (identifier)
resistance_r_pu_on_100mva
Type
decimal
Sample
                       
Reactance [X] (pu on 100MVA)
Reactance per unit on 100MVA.

No description available for this field.

Name (identifier)
reactance_x_pu_on_100mva
Type
decimal
Sample
                       
Susceptance [B] (pu on 100MVA)
Susceptance per unit on 100MVA.

No description available for this field.

Name (identifier)
susceptance_b_pu_on_100mva
Type
decimal
Sample
                       
Winter Maximum Continuous Rating (MVA)
Maximum continuous rating of cable subject to winter conditions in MVA.

No description available for this field.

Name (identifier)
winter_maximum_continuous_rating_mva
Type
text
Sample
                       
Summer Maximum Continuous Rating (MVA)
Maximum continuous rating of cable subject to summer conditions in MVA.

No description available for this field.

Name (identifier)
summer_maximum_continuous_rating_mva
Type
text
Sample
                       
Spring/Autumn Maximum Continuous Rating (MVA)
Maximum continuous rating of cable subject to spring/autumn conditions in MVA.

No description available for this field.

Name (identifier)
spring_autumn_maximum_continuous_rating_mva
Type
text
Sample
                       
Length (km)
Length of cable in kilometres.

No description available for this field.

Name (identifier)
length_km
Type
text
Sample
                       

JSON Schema

The following JSON object is a standardized description of your dataset's schema. More about JSON schema.

{
  • "title":"spd-ltds-appendix-1-circuit-data-table-1",
  • "type":"object",
  • "oneOf":
    [
    • {
      • "$ref":"#/definitions/spd-ltds-appendix-1-circuit-data-table-1"
      }
    ]
    ,
  • "definitions":
    {
    • "spd-ltds-appendix-1-circuit-data-table-1":
      {
      • "properties":
        {
        • "records":
          {
          • "type":"array",
          • "items":
            {
            • "$ref":"#/definitions/spd-ltds-appendix-1-circuit-data-table-1_records"
            }
          }
        }
      }
      ,
    • "spd-ltds-appendix-1-circuit-data-table-1_records":
      {
      • "properties":
        {
        • "fields":
          {
          • "type":"object",
          • "properties":
            {
            • "grid_supply_point":
              {
              • "type":"string",
              • "title":"Grid Supply Point",
              • "description":"The unique name of the Grid Supply Point (GSP) a substation is within."
              }
              ,
            • "circuit_from":
              {
              • "type":"string",
              • "title":"Circuit From",
              • "description":"Powerfactory code for starting node of circuit."
              }
              ,
            • "circuit_to":
              {
              • "type":"string",
              • "title":"Circuit To",
              • "description":"Powerfactory code for ending node of circuit."
              }
              ,
            • "no_of_ccts":
              {
              • "type":"integer",
              • "title":"No of ccts",
              • "description":"Number of circuits."
              }
              ,
            • "voltage_kv":
              {
              • "type":"integer",
              • "title":"Voltage (kV)",
              • "description":"The operating voltage of the asset. HV >= 6.6kV and < 33kV EHV = 33kV Transmission: Generally 132kV and above, but includes some lower voltages managed by our SPT licence area."
              }
              ,
            • "resistance_r_pu_on_100mva":
              {
              • "type":"number",
              • "title":"Resistance [R] (pu on 100MVA)",
              • "description":"Resistance per unit on 100MVA."
              }
              ,
            • "reactance_x_pu_on_100mva":
              {
              • "type":"number",
              • "title":"Reactance [X] (pu on 100MVA)",
              • "description":"Reactance per unit on 100MVA."
              }
              ,
            • "susceptance_b_pu_on_100mva":
              {
              • "type":"number",
              • "title":"Susceptance [B] (pu on 100MVA)",
              • "description":"Susceptance per unit on 100MVA."
              }
              ,
            • "winter_maximum_continuous_rating_mva":
              {
              • "type":"string",
              • "title":"Winter Maximum Continuous Rating (MVA)",
              • "description":"Maximum continuous rating of cable subject to winter conditions in MVA."
              }
              ,
            • "summer_maximum_continuous_rating_mva":
              {
              • "type":"string",
              • "title":"Summer Maximum Continuous Rating (MVA)",
              • "description":"Maximum continuous rating of cable subject to summer conditions in MVA."
              }
              ,
            • "spring_autumn_maximum_continuous_rating_mva":
              {
              • "type":"string",
              • "title":"Spring/Autumn Maximum Continuous Rating (MVA)",
              • "description":"Maximum continuous rating of cable subject to spring/autumn conditions in MVA."
              }
              ,
            • "length_km":
              {
              • "type":"string",
              • "title":"Length (km)",
              • "description":"Length of cable in kilometres."
              }
            }
          }
        }
      }
    }
}

Reuses

Click to expand Click to collapse

Submit a reuse

Click to expand Click to collapse

Your last name will be publicly displayed with your reuse

Your first name will be publicly displayed with your reuse

Your email will not be published publicly and will only be used by the administrators to contact you.

Short description of your work (max. 50 characters)

A longer description of what you achieved using this dataset (max. 1000 characters)

An URL where your work can be accessed publicly

 or 

(optional) An URL or an image which illustrates your work

false

Similar datasets

  • The "SPM LTDS Appendix 1 Circuit Data (Table 1)" dataset provides the data that is derived from power system analysis software, and therefore the circuit parameters detailed in the tables are based on the equipment between analytical node points. As some circuits may have intermediate node points, or a number of components, this aspect should be taken into consideration when assessing overall (…
  • The "SPD LTDS Appendix 6 Connection Activity" dataset provides an indication of areas of interest, or activity in the SP Distribution system from a connection perspective, the connection activity has been collated and displayed in Table 6, together with an indication of source substations.
  • The "SPD LTDS Appendix 2 Transformer Data (Table 2)" dataset provides the equipment parameter data for each group of transformers on the SP Distribution (SPD) system. The insertion of N/K in the table indicates where a parameter has not been verified.
  • The "SPD LTDS Appendix 9 System Schematics" dataset contains the schematic diagrams of the distribution system. The 33kV network is represented, down to the 11kV primary busbars.